Application
Examples FES2402, FES4802, and FES9604
The FES2402 has 24 10/100 Base-T ports and two copper and fiber Gigabit Ethernet ports. Two of the ports can be active simultaneously, providing redundant 1 Gb/sec links to a server or a backbone uplink. The FES4802 has 48 10/100 Base-T ports and two copper and fiber Gigabit Ethernet ports. Two of the ports can be active simultaneously to provide redundant 1 Gb/sec links to a server or a backbone uplink. The FES9604 has 96 10/100 Base-T ports and four copper and fiber Gigabit Ethernet ports. Four of the Gigabit Ethernet ports can be active simultaneously. The FES9604 is the alternative to a chassis-based switch in wiring closets. The FES2402-POE and FES4802-POE wiring closet switches provide additional support for both non-POE and POE devices, providing the means for integrating data, voice, and video over existing Ethernet cables. For more information about POE devices, see the section "Power over Ethernet". The FES X-Series and FWS X-Series provide high port density within a stackable form factor. You can deploy the FES and FWS X-Series devices within an enterprise network. With 10 Gigabit Ethernet uplinks (optional) for LAN PHY, you can deploy the FES and FWS X-Series within a Metropolitan Area Network (MAN). This section provides topology examples. Enterprise
Application Power
over Ethernet Foundry's FES2402-POE and FES4802-POE devices provide Power over Ethernet (POE), compliant with the standards described in the IEEE 802.3af specification for delivering in-line power. The 802.3af specification defines the standard for delivering power over existing network cabling infrastructure, enabling multicast-enabled full streaming audio and video applications for converged services, such as, Voice over IP (VoIP), WLAN access points, IP surveillance cameras, and other IP technology devices. POE technology eliminates the need for an electrical outlet and dedicated UPS near IP powered devices. With power sourcing devices, such as Foundry's FES2402-POE and FES4802-POE, power is consolidated and centralized in the wiring closets, improving the reliability and resiliency of the network. Because POE can provide power over Ethernet cable, power is continuous, even in the event of a power failure. Terms
Used in This Section Power sourcing device/equipment - This is the source of the power, or the device that integrates the power onto the network. Power sourcing devices/equipment have embedded POE technology. In this case, the power sourcing devices are Foundry's FES2402-POE and FES4802-POE. IP powered device or Power consuming device - This is the Ethernet device that requires power and is situated on the other end of the cable opposite the power sourcing equipment. Methods for Delivering POE There are two methods for delivering power over the network, as defined in the 802.3af specification: Endspan - Power is supplied through the Ethernet ports on a power sourcing device. Power is carried over live wire pairs that deliver data. With the Endspan solution, four wires are used to deliver data and power over the network. Midspan - Power is supplied by an intermediate power sourcing device placed between the switch and the powered device. Power is carried over the spare twisted pairs of wires. With the Midspan solution, eight wires are needed to deliver data and power over the network. With both methods, power is transferred over four conductors, between the two pairs. 802.3af-compliant powered devices are able to accept power from either pairs. Foundry's FES2402-POE and FES4802-POE devices use the Endspan method, compliant with the 802.3af standard. The Endspan and Midspan methods are described in more detail in the following sections.
With the Endspan solution, four wires deliver data and power over the network. Specifically, power is carried over the live wire pairs that deliver data, as illustrated in Figure 2.6. When using the same live wire pairs that deliver data, different frequencies enable power and data signals to traverse the same pairs of wires. Since data and power travel over different frequencies, the integrity of the data signals is not effected. Midspan
|
|
| Foundry Networks | | FES 4802 | |
|
| CLICK HERE
TO MAKE AN ENQUIRY or contact us at our Keison UK or USA offices |
|
PO Box 2124, Chelmsford, CM1 3UP England Tel: +44 (0)1245 600560 Fax: +44 (0)1245 600030 Email: info@keison.co.uk |
233 Rogue River Highway #425, Grants Pass Oregon 97527-5429, USA Tel: +1 541 956 9929 Fax: +1 541 610 1646 Email: info@keison.com |
| Home | Translate | Products | Catalogue | Enquiries | Links | Sitemap | Link to Us | ISO9001 | |
© Copyright 2005 Keison International plc - All Rights Reserved |
|