Oldham GD10PE

Teledyne Oldham GD10PE IR Extended Point Gas Detector

The GD10PE is designed for critical applications involving large volumes of air with high velocity. In places where you need fast reliable detection of low gas concentrations. GD10PE is in a class of its own.

Key Features

  • Solid-state IR sources (SimSourceTM) for superior long term performance compared to filament lamps
  • No recalibration, monitors and accounts for all changes in optical path thanks to true dual path, double compensation optical design
  • Selectable response rate
  • Dual-layer weather protector (No mesh, gauze, hydrophobic filters or sinters = No delay, no failure on demand)
  • Early dirty optics warning for improved preventative maintenance
Get a Quote
Oldham

Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.

The versatile GD10PE is suitable for monitoring, among others, the HVAC air intakes of living quarters, temporary refuges and local equipment rooms. In addition the ventilation air and combustion air intakes of gas turbines can be monitored along with the ventilation air extract duct, the only location where you can guarantee to detect a gas leak on a turbine package. With a measuring range of 0-20% LEL the GD10PE is 5 times more sensitive than standard point detectors.

The GD10 range of infrared gas detectors differ from all other models, because they utilise silicon based solid-state infrared sources. The complete optomechanical design and construction is so stable that an ultra-fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs. An industry-standard HART® interface is used for configuration of the levels as well as access to maintenance data. Features and benefits include an independently heated mirror and lens for high-performance detection in rough environmental conditions and guaranteed continuous operations at 85°C which make this instrument suitable for turbine ventilation extract ducts.


General
Detection method Ir-absorption, dual-wavelength, dual path
Ir-source Solid-state ir source, 50hz flash
Detection range 0-20% Lel (0-1% vol. ) Methane
Gases detected Hydrocarbons
Self-test Continuous
Calibration Factory set, no field recalibration
Performance
Accuracy
Refers to -20°c to +60°c
(-4°f to +140°f)
±1% Lel (0-10% lel reading)
±1.4% Lel (10-20% lel reading)
Response time
Detector reading: 100% Lel test gas: 20% Lel test gas:
4% LEL 0.6 Sec. 1Sec.
10% LEL 0.9 Sec. 2.5 Sec.
18% LEL 1.3 Sec. 6 Sec
Output signal
Standard Current source 4 – 20 mA, max. Load
Impedance 500 ohm
Option Current sink 4 – 20 mA
Hart® Maintenance and configuration
Detector warnings:
- Early clean optics
- Dirty optics
- Detector failure
Configurable (HART)
Pre warning (2 mA)
Dirt accumulation (1 mA)
Internal fault (0 mA)
Electrical
Power supply 24V DC, range (18 - 32V DC)
Power consumption Approx. 3.5 W
Connection 3 Wires (0.5mm2- 2.5 mm2)
Cable entry M20 exe cable gland
Temperature range
Storage 40°C to + 70°c (-40°f to +158°f)
Operating -40°C to + 65°C (-40°F to +149°F)
Probe, inside duct Up to +85°c (185°f)
Humidity (operation) 100% RH
Explosion proof housing
Main compartment Exd IIC T6
Terminal comp Exe
Protection category Ip66/ip67 din 40050
Housing material Stainless steel SIS2343 (ASTM316)
Dimensions (lxwxh) 104 X 105 (mm)
30.9 X 4.1 X 4.1 (Inches) overall
Weight (detector) Approx. 6.5 Kg (14.3 Lbs)
Weather protection Approx. 0.3 Kg (0.7 Ibs
Duct mount kit Approx. 2. 1 Kg (4.6 Ibs)
Warranty
5 Years full warranty on a complete instrument
15 Years warranty on the IR-sources
Approvals
ATEX II 2G Ex d e IIC T5/T6 Gb
CSA Ex d e IIC T5/T6 Gb
IECEx Ex d e IIC T6 Gb
INMETRO Ex d e IIC T6 Gb
SIL 2/3 TüV 968/FSP 1186.00/15
Versions
Gas Ranges
Methane 0-20%Le
Ethylene 5,000 Ppm
Other versions are available, please contact your dealer
Accessories
Weather protection Required for standard installation
Sample flow housing For sampling systems and testing
Duct mount kit For through-wall installation

Reference Description
GD10PE Detectors Weather protection, sample flow tube and duct mount kit are not included.
Order separately
C2H4 Ethylene
GD10-PE0-03AM-0XH-00 GD10PE Detector C2H4 Ethylene 5000 ppm, SS 316L, ATEX, IECEx, INMETRO, 4-
20mA, source, HART (Config 2913)
CH4 Methane
GD10-PE0-17DE-0XH-00 GD10PE Detector CH4 Methane 20% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-
20mA, source, HART (Config 2921)
GD10-PE0-17DE-0XJ-00 GD10PE Detector CH4 Methane 20% LEL, SS 316L, ATEX, IECEx, INMETRO, 4-
20mA, sink, HART (Config 2962)