HomeGas AnalysersSafety › Sieger ACM 150 FT-IR Centralised Gas Monitoring System


Sieger ACM 150 FT-IR Centralised Gas Monitoring System


The ACM 150 by Sieger uses Fourier Transform Infrared Technology, that is trusted and proven, in order to detect a wide array of volatile chemicals.

Free of cross interference, the ACM 150 FT-IR Centralised Gas Monitoring System identifies each gas using its infrared fingerprint, whilst also being able to identify odors or chemicals that are unknown. New gases can be added to the system at any time.

The ACM 150 can detect percent (%) levels for flammable gas monitoring or PPM levels for the monitoring of toxic gases by choosing between two sample cells.

The system can be accessed remotely by using a web browser in order to change alarm configurations or gas selections. This can also be done using the front panel.

Features & Benefits

  Detects virtually any gas, chemical or odor in an industrial process
  Up to 40 measuring points can be sequentially detected
  Simplified touchscreen operation

Quick Specs

  Analysis method: Continuous scan FT-IR (Fourier Transform Infrared) analyser

  Gas cell path: 5.0 m path length
  Scanning rate: less then 15 sec per point


Brochure
Gas List
Specifications
Manual

Ordering Information


ACM 150 Base Unit

76-ACM150-115-1 FTIR-based analyser, for measurement of up to 14 gases per sample point. Includes primary venturi pump with automatic switch-over to electric backup pump, touchscreen user friendly interface (point and click), built-in diagnostics, configurable gas selection, web-based user interface, 10 point sample valve assembly including dust filter, 80 user-programmable relay contacts; requires method(s) for detection of gases according to customer's gas list. Power requirements: 115VAC, 5.0m path length gas cell
76-ACM150-115-2 FTIR-based analyser, for measurement of up to 14 gases per sample point. Includes primary electric pump with automatic switch-over to electric backup pump, touchscreen user friendly interface (point and click), built-in diagnostics, configurable gas selection, web-based user interface, 10 point sample valve assembly including dust filter, 80 user-programmable relay contacts; requires method(s) for detection of gases according to customer's gas list. Power requirements: 115VAC, 5.0m path length gas cell
76-ACM150-230-1 FTIR-based analyser, for measurement of up to 14 gases per sample point. Includes primary venturi pump with automatic switch-over to electric backup pump, touchscreen user friendly interface (point and click), built-in diagnostics, configurable gas selection, web-based user interface, 10 point sample valve assembly including dust filter, 80 user-programmable relay contacts; requires method(s) for detection of gases according to customer's gas list. Power requirements: 230VAC, 5.0m path length gas cell
76-ACM150-230-2 FTIR-based analyser, for measurement of up to 14 gases per sample point. Includes primary electric pump with automatic switch-over to electric backup pump, touchscreen user friendly interface (point and click), built-in diagnostics, configurable gas selection, web-based user interface, 10 point sample valve assembly including dust filter, 80 user-programmable relay contacts; requires method(s) for detection of gases according to customer's gas list. Power requirements: 230VAC, 5.0m path length gas cell

ACM 150 Options and Accessories

76-150-14393-04-B 10-point Sample Manifold includes Dust Filter. Up to 3 max may be added to base unit - 40 points total
76-165-14594-00-A Kit, Line Leak,3/8T Check Valve Note: 1 per sample point required.
RSD0013 Set up of method
0235-0252 FEP tubing 0.25" ID x 0.375" OD, 300m length
76-215-12477-00-B ACM internal hardware for Line Leak Option for dual electric pump systems.
76-215-12475-00-D ACM internal hardware for Line Leak Option for Venturi pump systems.

ACM 150 Serial Communications Interfaces

76-150-14392-02 Kit, Data Interface, Control Net B3514
76-150-14398-02 Kit, Data Interface, Control Net, Redundant B3514
76-150-14391-10 Kit, Data Interface, Modbus TCP/IP
76-150-14390-04 Kit, Data Interface, Profibus DP

ACM 150 Spares

76-465-15101-00 PKI bench w/plate
76-441-15551-00 Gas cell for PKI bench
76-519-13251-00 Single board computer
76-518-13260-00 15" HMI touch screen computer
76-150-15300-00-B Network switch, Cisco, including bracket
76-150-14500-00-B DVD/CD-ROM drive with mounting brackets

ACM 100 Upgrade Kits

76-165-14582-00-A Kit, Dust Filter 3/8
76-150-15500-00-A Complete upgrade - Bench upgrade and HMI upgrade
76-150-15101-00-H ACM 100 Bench upgrade kit: new PKI bench w/plate, single board computer, shelf, mounting hardware, gas cell, cables
76-150-15400-00-A ACM 100 HMI upgrade kit: new touch screen, network switch, mounting hardware (door etc.), new software
76-215-12477-00-B ACM internal hardware for Line Leak Option for dual electric pump systems. Note: Assy, Line Leak requires qty 1 off item 76-220-13588-00-A when used as a replacement for ACM 100.
76-215-12475-00-D ACM internal hardware for Line Leak Option for Venturi pump systems. Note: Assy, Line Leak requires qty 2 off item 76-220-13588-00-A when used as a replacement for ACM 100.
76-220-13588-00-A Assy, Adaptor Solenoid Valve for new plug
76-120-15050-00 Software ACM 100 Archiving Tool



Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.

Back To Last Page

Sieger

Fixed Gas Detectors

705 HT Sensor
FS20X Fire and Flame Detector
FS24X Flame Detector
FSL100 Series Flame Detectors
MeshGuard
OELD (Optima Excel Local Display)
ProRAE Guardian
RAEGuard 2 PID Fixed Detector
Searchline Excel Cross-Duct
Searchline Excel Infrared Open Path
Searchline Excel Kits with XNX Transmitters
Searchpoint Optima Plus
Sensepoint
Sensepoint with Junction Box
Sensepoint XCD
Sensepoint XCL
Sensepoint XRL
Series 3000 MkII and MkIII
SS4 UV and UV/IR Flame Detectors
System 57
Touchpoint Plus 19" Rack
Touchpoint Plus Controller
Touchpoint Pro
Unipoint Controller
XNX Universal Transmitter

Semi High Tech

ACM 150 FT-IR Centralised Gas Monitoring System
Chemcassette Toxic Gas Detection
ChemKey TLD Toxic Gas Detector
CM4 Continuous Multipoint Monitor
Fire Sentry FS7 Flame Detector
LeakFilm Liquid Leak Detector
Midas Gas Detector
Satellite XT
SPM Flex Chemcassette
SPM Single Point Monitor
Vertex M Hazardous Gas Monitor
Vertex Multi-Point Toxic Gas Monitoring System

Tubes & Pumps

Colorimetric Gas Detection Tubes and Pump

Want A Quotation?

Please fill out the following fields and we will e-mail you a quotation shortly.