Home › Laboratory › Spectrophotometers › Bibby Scientific 6800 Double-Beam Spectrophotometer
Bibby Scientific 6800 Double-Beam Spectrophotometer
Please note - this product is now obsolete. Please click here for the current models.
True double beam with highly stable symmetrical optics
1.5nm spectral bandwidth
Bibby Scientific Flight Deck Software included
A range of easy to fit accessories
The Bibby Scientific Model 6800 Spectrophotometer is built on a solid foundation of high quality sealed optics for optimum photometric performance. The user-friendly Flight Deck software ensures that operation of the Model 6800 is a simple and productive experience and gives access to the most comprehensive range of features and functions available at this level. The operating modes of the Model 6800 include:
Photometrics & Multi-Wavelength: Measure the absorbance or transmittance at one to six designated wavelengths or calculate the ratio and difference of two or three selected wavelengths using the dedicated 'Ratio Mode.' All results are displayed in a simple tabular format and an alphanumeric identity can be entered for each sample.
Spectrum Scanning: Scan in the range 190 to1100nm with resolutions up to 0.1nm and scan speeds up to 3600nm/sec. All data is displayed in both graphical and tabular formats with automatic peak and valley identification as well as manual selection. Post scan manipulations allow multiple overlays, spectrum calculations and derivative spectra to be displayed.
Time Scan & Kinetics: Measure the changes in absorbance or transmittance over 30 to 99999 seconds. The concentration or activity values are then calculated from the display by the free selection of a start and end time for which a regression curve is displayed and calculations made against an adjustable K factor.
Quantitation: Enables the accurate measurement of sample concentrations against calibration curves (K factor, 1st to 3rd order) based on up to twenty standards and up to three wavelengths for multi-component analysis. The easy recall of saved calibration curves leads to quicker, more accurate analysis.
DNA/RNA: Offers standard methods for measuring DNA, RNA or oligonucleotide concentrations using the absorbance values recorded at 260 and 280nm.
Protein Measurements: Offers pre-set methods for measuring protein concentrations using the Bradford, Lowry, BCA and Direct UV protocols. Any of the default settings can be modified allowing specific user variations to any of these standard test protocols.
|
The Bibby Scientific Flight Deck software also allows the easy import/export of results and methods ensuring that standard methods and procedures are carried out quickly and accurately, minimising the potential for user error. With a single click of the mouse the Model 6800 exports raw data and results to Excel for further processing or saving, maximising the time the unit can perform measurements.
The applications of the Bibby Scientific Model 6800 are extended further by the range of accessories. These include a water heated cell holder for temperature control from ambient to 40 degC, a micro cell holder for sample volumes down to 50uL and a variable path length cell holder for path lengths up to 100mm. Holders for glass filters and flexible films further compliment this range. All accessories can be easily fitted or changed by the operator by simply releasing a fixing screw.
Data Sheet Manual
|
Ordering Information
Pre-configured instruments
680-SC - Model 6800 Double Beam Spectrophotometer supplied with Single Cuvette holder (10x10mm cuvettes, sample and reference), Flight Deck PC Software on
CD ROM and interconnection cable (PC required but not supplied - cuvettes not supplied).
680-MC - Model 6800 Double Beam Spectrophotometer as with 680-SC but with Micro Cuvette holder fitted (sample and reference - cuvettes not supplied).
680-LC - Model 6800 Double Beam Spectrophotometer as with 680-SC but with Long Path Length Cuvette holder
fitted for 10, 20, 30, 40, 50 or 100mm path length cuvettes (sample and reference - cuvettes not supplied).
680-TC - Model 6800 Double Beam Spectrophotometer as with 680-SC but with Water Thermostated Cuvette holder fitted (10�-10mm cuvettes, sample and reference, requires temperature controlled water circulator - cuvettes not supplied).
Accessories
Can be supplied fitted to the Model 6800 using the product configurator or as additional accessories requiring fitting by the customer.
680 081(01) - Single Cuvette holder, sample and reference, for standard
10mm cuvettes.
680 031(02) - Micro Cuvette holder for sample volumes down to
50 micro-litres.
680 061(03) - Glass Filter holder for slides, lenses and filters.
680 101(04) - Film holder for thin, flexible sheet materials such as plastic,
acrylic, gelatine, etc.
680 111(05) - Long Path Length Cuvette holder for use with 10, 20, 30, 40,
50 or 100mm path length cuvettes.
680 131(06) - Water Thermostated Cuvette holder for use with a
temperature controlled water circulator and 10mm cuvettes.
Note: The order codes in brackets are for use with the Product Configurator only.
Lamps
068 020 - Tungsten halogen
068 021 - Deuterium
Glass & Quartz Cuvettes
035 027 - Visible (glass) 10mm path length cuvette
035 086 - Visible (glass) 20mm path length cuvette
035 029 - Visible (glass) 40mm path length cuvette
035 087 - Visible (glass) 50mm path length cuvette
035 079 - Visible (glass) 100mm path length cuvette
035 123 - Visible (glass) micro (500�µl) cuvette
035 126 - Visible (glass) semi-micro (1ml) cuvette
035 028 - UV (quartz) 10mm path length cuvette
035 124 - UV (quartz) ultra-micro (50�µl) cuvette
035 125 - UV (quartz) micro (500�µl) cuvette
035 127 - UV (quartz) semi-micro (1ml) cuvette
|
Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.
Back To Last Page
|
|